General Printing Technical details Sustainability certificates ENERGY STAR Design Ports & interfaces Performance Paper handling Operational conditions Packaging content Quick start guide Weight & dimensions Power The printer is ready. Typically, this sensor will need to be placed so that it will pass under the part of the tag with the most surface area (for the Gap sensor), or the part of the tag with the black mark (for the Mark sensor). The printhead is over temperature. STATUS light flashing red. Application to manage Link-OS printers directly from the SOTI MobiControl environment across wireless and Ethernet infrastructures. The status information that these lighting patterns represent is detailed in this section. . The EPL format is very specific in the structure, so verify that all data components are correctly placed. Then select the Command name: Reset printer. Discover useful answers or post a question. 0000008259 00000 n By default this is Hex 5E but can be altered in some environments. Version 8.6.5.26125This is the recommended driver to use with your printer. Detailed steps can be seen in the video Setting Up Your Zebra ZT410 Printer. Printer Discontinuation Date:October 1, 2020 987 KB, Download Print job leaves the print queue but nothing is printed. Additional font packages for barcode label printers. View the manual for the Zebra ZT410 here, for free. 893 KB, Download This manual is available in the following languages: English. You can accessthelocalized User Guidesin the MANUALS section. how i can see the history in printer zt410 dpi 203 ? 'ZDesigner Printer Driver' is compatible with ZebraDesigner 3 and prior versions.OPERATING SYSTEM versions: Windows 10/11, Windows Server 2016/2019/2022 (see Release Notes for details) How to Install Driver v5, Version 1.14.1.143Use this OLE for Retail POS driver to develop applications that are compatible with the Unified POS specification. No action necessary 3. Hi, How do I switch the settings to always print Direct Thermal and not Thermal Trans labels so I don't have to switch it each time? Please see the video in Setting Up Your Zebra ZT410 Printer for more information on where to place the red laser sensor for your particular tag. This site uses cookies to manage user authentication, analytics, and to provide an improved digital experience. how do I reload a new roll of shipping labels. Find the right solution. but whichever engineer decided a flashing green light . fixed by Zebra Factory Repair. If using ZPL, make sure the format prefix (i.e.. For ZPL Printers, view the Configuration Label and check that the format prefix matches the data being sent from your application. A WLAN error condition exists. Resetting size: You will want to check both in Printing Preferences and the Printing . 0000001303 00000 n The control panel (ZT230 printer only) displays: 9. No label are fed out of printer when print job is sent from host. And see how to overcome the common problems of settings not being saved or the. Title . Status Indicator Patterns on the ZebraNet Print Server II Solid Green - hardware is functioning properly and it has detected the presence of the network. Data LED on printer is flashing but the printer is not printing. Use our interactive tool to find and print disinfecting instructions for your Zebra mobile computer, printer or scanner. 0000018619 00000 n Need to know the Country of Origin of the ZT410? 'ZDesigner Printer Driver' is for use with ZebraDesigner 3 and other Windows applications.OPERATING SYSTEM versions: Windows 10/11, Windows Server 2016/2019/2022 (see Release Notes for details) How to Install Printer Driver v8, Version 1.1.9.1297Use this software to configure your printer after Printer Driver installation.OPERATING SYSTEM versions: Windows 10/11, Windows Server 2016/2019/2022 (see Release Notes for details) How to Configure Printer Settings with Zebra Setup Utilities, Version 5.1.17.7412Use this driver if you need to use either CPCL or EPL printer command languages. Contact Us, 0000008027 00000 n STATUS light steady yellowSUPPLIES light flashing yellow. applicable to Zebra Printers that use ZPL or EPL printer language resolution / answer Cause or Overview You cannot send a plain text file to the printer and expect a label response. In the Properties screen, click on Printing Preferences. 2. The printer is on and in an idle state. v`Bl7;at}-U=$ge~_&EYmS1np2~^. NETWORK light offA radio was found during power-up. This will print straight ASCII hex characters. The following details are to ensure the printer and source format data are correctly matched. The data light is flashing green like it is waiting on data and the screen will flash multiple screens back and forth. Once these settings have been adjusted, you should be able to feed one tag at a time when the print head is closed and the feed button is pressed on the printer. As soon as all of the data has been received, the status LED will turn You cannot send a plain text file to the printer and expect a label response. NETWORK light offNo Ethernet link is available. In the Printing Preferences, click on the Tools tab. flag Report Data LED on the printer is flashing but the printer is not printing. Printing will stop until the print head cools to an acceptable printing purpose and non-infringement. The power supply is over temperature. Applies To Zebra Printers that use ZPL or EPL printer language Cause or Overview You cannot send a plain text file to the printer and expect a label response. This month w Today in History: 1990 Steve Jackson Games is raided by the United States Secret Service, prompting the later formation of the Electronic Frontier Foundation.The Electronic Frontier Foundation was founded in July of 1990 in response to a basic threat to s We have already configured WSUS Server with Group Policy, But we need to push updates to clients without using group policy. %PDF-1.6 % Interpreting the status light colours and patterns, such as flashing red light, solid green . It is on a rather larger network. More information can be found by downloading the Zebra GK420D Manual. Maintenance that delivers the right plan for your business goals and budget. STATUS light steady red PAUSE light steady redDATA light steady red. PAUSE light steady yellow. Load a roll of media, following the instructions in Loading the Media on page 9 of users guide. If the printer does not receive the correct language (sending incorrect commands or using the wrong driver selection), the printer will not respond.Zebra printers use their native print language to generate a label. Software to develop customized label templates. 0000005035 00000 n To reset your Zebra printer, make sure it is completely turned off. When it does, the printer will automatically resume operation. Install a genuine Zebra printhead to continue. ZT410 ZT420 Maximum Print Width 4" 6" Maximum Ribbon Length 450 m 450 m Maximum Print Speed 14 ips 14 ips User Interface LCD LCD Print Resolution 203, 300, 600 dpi 203 and 300 dpi Printer Control Language ZPL, EPL, others ZPL, EPL, others To verify that the settings are correct, navigate to RFID -> Read RFID Data and select "Read" to ensure that each tag responds with its EPC as it is fed through the printer. Do you have a question about the Zebra and the answer is not in the manual? 0000002791 00000 n Zebra ZT410 ZPL Clear buffer command. Powered by Help Scout, How to Manually Calibrate the Zebra ZT410 Printer. The printhead was replaced with one that is not a genuine Zebra printhead. Printer Discontinuation Date: October 1, 2020 Zebra label printers are great for the small business. Data LED on the printer is flashing but the printer is not printing. Solution: Please print the sensor chart, calibrate the sensor or load the printer defaults. 49 28 See your Users Guide or the links below for the procedure. Application to create printer configuration and manage Link-OS printers remotely from a single location. 0000042347 00000 n lighting patterns of green, orange and yellow. The Print Server II has a hardware problem that can only be 0000008140 00000 n `:()ckMtX%$l\30$~+S ` BG endstream endobj 50 0 obj <>>> endobj 51 0 obj >/PageWidthList<0 612.0>>>>>>/Resources<>/ExtGState<>/Font<>/ProcSet[/PDF/Text/ImageC]/Properties<>/Shading<>/XObject<>>>/Rotate 0/TrimBox[0.0 0.0 612.0 792.0]/Type/Page>> endobj 52 0 obj <> endobj 53 0 obj <> endobj 54 0 obj <>stream 0000004465 00000 n 2. You can learn more about the cookies we use as well as how you can change your cookie settings by clicking here. Notice: Zebra Technologies The printer has failed its power on self test (POST). Data LED on printer is flashing but the printer is not printing No label are fed out of printer when print job is sent from host. 0000002306 00000 n Use the hex dump feature and examine the data being received. = Unit is in Netware firmware update mode. Service and Support Discontinuation Dates: NETWORK light steady green. Printers with a ZebraNet wired Ethernet option. 0000004241 00000 n The printer needs attention and cannot continue without user intervention. %PDF-1.7 % There are several languages a Zebra Printer may require, including ZPL or EPL. 0000011050 00000 n Compare the features to see which printer best suits your needs. h2P0Pw/+Q0L)61 The better your problem and question is described, the easier it is for other Zebra owners to provide you with a good answer. These steps should help the user to identify and resolve issues with printing various tags. Can you still ping it? Is your question not listed? endstream endobj 115 0 obj <>stream ! STATUS light flashing yellow. You may find the answer to your question in the FAQs about the Zebra ZT410 below. ZPL and EPLcan be sent to the printers as ASCII text but must be in the correct command format. This indicator light flashing indicates one of the following: The printhead is under temperature. hb``b``>AX [^`@"* -utTB3CAg/Z)s^?;d[ZFGKhhhXE00x p *3I$ *`')3O`M? 0000011278 00000 n 49 0 obj <> endobj xref If your tags are not feeding out one at a time, you will need to perform a full media calibration. Inspect the platen roller (underneath printhead) and make sure there are no cuts in it or labels wrapped around it. The PAUSE light turns off. All Rights Reserved. 2 MB, Download These settings can be adjusted in the Settings -> Media Type settings menu. No labels are fed out of the printer when the print job is sent from the host. ^XA ^FO20,20^A0N,40,40^FDTest Text ^FS .. and so on. Custom printer menu examples in WML and XML programming languages. 2023. ZPL and EPLcan be sent to the printers as ASCII text but must be in the correct command format.ZPL Example: This information takes some understanding of the details associated with the printer and its settings related to the programming language. The indicator lights on the control panel show the current status of the printer. 1= {K This topic has been locked by an administrator and is no longer open for commenting. There are several languages a Zebra Printer may require, ZPL or EPL. Adjust the printer settings usingZebra Setup Utilities software or Windows Printer Driver v8. The 2 main languages supported by Zebras Desktop and Tabletop printers are ZPL and EPL. STATUS light steady red SUPPLIES light flashing red. Basically the following details making sure the printer and source format data are properly matched. endstream endobj 113 0 obj <>stream The feed button doesn't work. Bluetooth Troubleshooting | Zebra Printer. Industrial Printers, Certified Refurbished and Buy-Back Programs, General Purpose Handheld Barcode Scanners, General Purpose Hands-Free and On-Counter Scanners, Hospital Bracelet and Patient ID Barcode Wristbands, Handheld RFID Readers and RFID-enabled Scanners, Fixed Industrial Scanner and Machine Vision Selector Tool, Industrial Machine Vision Fixed Scanners Accessories, Fixed Industrial Scanner and Machine Vision Support, Machine Vision and Fixed Scanner Software, Irreversible Heat and Reversible 18C Indicators, Fixed Industrial Scanners and Machine Vision, Installing the Drivers andRunning the Printer Installation Wizard, Connect the printer to a USB port on your computer. When our label makers act up and I can't fix it after basic troubleshooting; replace drivers, replace cables, try from another computer, etc. File does not contain a form feed code that will advance sheet. Allow the printhead to cool. of the network. Pre-made printer administration files to protect you printer data and infrastructure. The media settings must match the actual media that you are using. Press the feed button to resume printing. The light flashes red while the printer associates with the network. Still need help? Refer to. Excellence in inspection. Select the Command Type: Action and the Command name: Load factory defaults. They are assigned a DHCP reservation, then the ports are created and printer is installed through the PrnInst.exe printer installation program provided with the Zebra driver. Utility to configure barcode label printers. To do this, you will need to determine if your tags require the "Mark Sensor", or the "Gap Sensor". Is the manual of the Zebra ZT410 available in English? Dust and particles block sensors field of view. Ask your question here. A 10Base-T link was found. . 158 KB, ZT410 and ZT420 Printers Initial Setup Details and Information, ZT410 and ZT420 Printers: Solving Media Out Errors and Calibrating the Printer, Resolving Print Quality Issues on ZT410 and ZT420 Printers, Troubleshooting Ribbon Out Error on ZT410 and ZT420 Printers, Changing the Wired TCP/IP Settings Through the ZT410 or ZT420 LCD Menu of the Printer, Access Zebra's knowledge base at the Support Community site, Common Printing Issues and Recommended Solutions are also available in the User Guide, Read about steps required to download Printer OS, Upgrade Printer OS (Firmware) using ZDownloader, Browse Zebra High Quality Supplies for Barcode, RFID and Card Printers, Manage Software Licensing (excluding Printers), Device Diagnostic Tool for Mobile Devices, How To Download Software Under End User Licensing Agreements, Report a Potential Security Vulnerability or Concern, If you connected your printer to a computer via USB before driver installation, the printer might appear as an unknown (unspecified) device in Devices and Printers.. The main logic board (MLB) is over temperature. The printer is paused. NETWORK light steady red. 0000004548 00000 n You can view an example of the output below. If you are having trouble printing your tags, there are a few steps you can take to try and resolve any errors you may be seeing. If your tags are separated by a either a gap or notch in the print media, set the printer settings to use the "Gap Sensor" settings. 1D, CODABAR (NW-7), Code 128 (A/B/C), Code 39, Code 49, Code 93, EAN13, EAN8, MaxiCode, MicroPDF417, PDF417, UPC-A, UPC-E, cTUVus, CE Marking, FCC-B, ICES-003, VCCI, C-Tick, \nNOM, S-Mark (Arg), CCC, CU, BSMI, KCC, SABS, IN-Metro, Final Steps for Peel-Off Mode (with or without Liner Take-Up), Navigating through Screens in the Display, Clean the Exterior, the Media Compartment, and the Sensors. limited to, implied warranties of merchantability, fitness for a particular Load a roll of ribbon, following the instructions in Loading the Ribbon on page 12 of users guide. This indicator light flashing indicates one of the following: The printhead is under temperature. green; then, the printer will automatically resume operation. Use the hex dump feature and examine the data being received. PDF Direct allows you to print PDF documents directly to Zebra Link-OS printers from ERP systems, such as Oracle and SAP, without middleware. Your daily dose of tech news, in brief. Printer is in dump mode but nothing prints after sending file. Diagnostic Mode A communication diagnostic test can be performed to troubleshoot data problems. failed POST. Use our interactive tool to find and print disinfecting instructions for your Zebra mobile computer, printer or scanner. Diagnostic Mode:A communication diagnostic test can be performed to troubleshoot data problems. Data Light is flashing but no labels print issue / question Data Light is flashing but no labels print applicable to ZT200 or ZT400 Printer resolution / answer If you have assured you are sending the proper label formats, check to see if the printer is in Peel Mode. Check power connections from the wall outlet to the power supply, and Meet your goals for associates, inventory and customer experiences with The Modern Store framework. I'd replace it or see if it can be serviced if it's under warranty. 0000004354 00000 n Select DIAGNOSTIC and then send a label format from the host computer. Then, resume printing. The printer has failed its power on self test (POST) If this error occurs right after you turn on the printer, contact an authorized reseller for assistance. The printer is on and in an idle state. h26U0P06S0P06W01R+-()$X;;\~p2 DYt First,verify that the printer is "seeing" the tags correctly. Slow flashing Green (1 time/second) - the unit is sending data to the parallel port on printer. 0000019381 00000 n The cables go into a hub and not directly connected. The Zebra ZT410 has the following certifications: cTUVus, CE Marking, FCC-B, ICES-003, VCCI, C-Tick, \nNOM, S-Mark (Arg), CCC, CU, BSMI, KCC, SABS, IN-Metro. See your printer'sUsers Guide or the links below for the procedure. Solid Red for more than 30 seconds- Unit has The printer is attempting to associate with the network. for any purpose. 22 MB, Download If the printer does not receive the correct language (sending incorrect commands or using the wrong driver selection) then the printer will not respond. Fast flashing Green 0000014807 00000 n Once the download has completed, open the installer by clicking on it. Click the button named "Next". Contact Us The printer is in Direct Thermal mode, which does not require ribbon; however, ribbon is installed in the printer. Then, press the feed button to resume printing. Red-Red-Green-Green I have swapped out both the Ethernet cable for the printer and the computer that is being used from. This information takes some understanding of the details associated with the printer and its settings related to the programming language. Please see the video in Setting Up Your Zebra ZT410 Printer for more information on where to place the red laser sensor for your particular tag. Check that the Zebra Protocol setting (view it on the Configuration Label) is set to set to NONE. IMPORTANT! 0000008402 00000 n Status indicator does not light when power switch is on (I) Check power connections from the printer to the outlet. If this error occurs after you have been printing, turn the printer power off and on. To view all the data you must have full width media, and ribbon if used, loaded Download the drivers for the Zebra ZD410 tag printer by clicking here. Solution 2: Make sure the printer isn't plugged into an outlet controlled by a light switch. 5 MB, Download 0000007992 00000 n This Zebra product is discontinued. the unit is sending data to the parallel port on printer. The printer is not connected to your network. Status Indicator Patterns on the ZebraNet 946 KB, Download endstream endobj 114 0 obj <>stream 0000017841 00000 n on. STATUS light steady green (other lights steady yellow for 2seconds during printer power-up). You cannot send a plain text file to the printer and expect a label response. from the power supply to the printer. If printing issues are observed, such as skipped labels, vertical image/label drift, or ribbon out or media out errors. If your printer was manufactured in December of 2019 or newer, hold down the feed button UNTIL the data light turns on and is blinking, indicating BT is in a pairing state. Welcome to the Snap! 881 KB, Download The main logic board (MLB) is over temperature. Flashback: March 1, 2008: Netscape Discontinued (Read more HERE.) If you require additional support, please contact aZebra Authorized Service Provider. Print job leaves the print queue but nothing is printed. (Each task can be done at any time. Status light: Steady yellow light Supplies light: Flashing yellow light Refer to the table below for possible causes and recommended solutions: If you have ZT210 or ZT220 models without LCD, you may need to set the print method in the printer driver. The media supply is out. No labels are fed out of the printer when the print job is sent from the host. The Setup guidelines below will take you to English documentation. Helpmaximize device availability and business operations withZebra OneCare Support Services. Check your printers specification to determine which language your printer supports. without warranty of any kind, either expressed or implied, including, but not Refer to the article: For EPL, make sure each line is terminated by a Carriage Return/Line Feed CR/LF. (9 times/second) - has not detected presence of network. This communication test will give the ability to see what data the printer is receiving. Refer to the article: Check that theZebra Protocol setting (view it on the Configuration Label) is set to NONE. I have a Zebra ZT410 that will print about 30 labels and then lock up and won't print anymore. The only way is to do a reset of the printer. error. Applicable To The data light starts flashing whenever a job is sent to print. Zebra Printers that use ZPL or EPL printer language. Any help would be great. Print Server II. Solution 3: Make sure there are labels in the printer. The light then flashes yellow while the printer is authenticating with the network. My ZT410 won't print anything. Click Send. Application to manage Link-OS printers directly from the AirWatch environment across wireless and Ethernet infrastructures. For ZPL Printers view the Configuration Label and check that the format prefix matches the data being sent from your application. In this series, we call out current holidays and give you the chance to earn the monthly SpiceQuest badge! Once the printer is reset, you will have to recalibrate and set it up again to get it working. The Zebra Printer requires all label requests to be in the proper programming label format, or the printer will not respond or print. Zebra printers use their own native print language to generate a label. Proven track and trace. The control panel (ZT230 printer only) displays: When the process is complete: The SUPPLIES light stops flashing. Pretty limited with them. Are you sending the printer the correct programming language required for your printer? Utility to upload printer OS / firmware and service packs to barcode label printers.